Anhui Feichun Kabel Khusus Co., Ltd

Type MP-GC Three-Conductor Mine Power Feeder Cable PVC Jacket 8kV Designed for Connections Between Units of Mine Distribution Systems
Feichun Type MP-GC Three-Conductor Mine Power Feeder Cable PVC Jacket 8kV Designed for Connections Between Units of Mine Distribution Systems
Applications :
These cables are designed for connections between units of mine distribution systems, suitable for installed in duct, conduit or open air and for direct burial in wet and dry locations.
Standards :
ICEA S-75-381/NEMA WC 58
ASTM B-8
CAN/CSA-C22.2 No.96 | ![]() |
Construction :
Conductor | Stranded annealed bare copper conductor. |
Conductor Shield | Conducting layer. |
Insulation | Cross-Linked Polyethylene (XLPE). |
Insulation Shield | Conducting layer + copper tape. |
Ground Check Conductor | Copper conductor with a yellow polypropylene insulation. |
Grounding Conductor | Tinned copper conductor. |
Jacket | Polyvinyl Chloride (PVC), black. |
Options :
Other jacket materials such as CSP/PCP/NBR/CPE/TPU are available upon request.
Mechanical and Thermal Properties :
Minimum Bending Radius: 12×OD.
Maximum Conductor Operating Temperature: +90℃.
Dimensions and Weight :
Construction | No. of | Grounding | Ground | Nominal Insulation | Nominal Jacket | Nominal Overall | Nominal Weight | Ampacity | ||||
No. of cores | - | AWG/ | AWG/ | inch | mm | inch | mm | inch | mm | lbs/kft | kg/km | A |
3×4 | 7 | 8 | 8 | 0.115 | 2.9 | 0.11 | 2.8 | 1.52 | 38.6 | 1366 | 2032 | 122 |
3×2 | 7 | 6 | 8 | 0.115 | 2.9 | 0.11 | 2.8 | 1.58 | 40.1 | 1727 | 2569 | 159 |
3×1 | 19 | 5 | 8 | 0.115 | 2.9 | 0.11 | 2.8 | 1.66 | 42.2 | 2174 | 3234 | 184 |
3×1/0 | 19 | 4 | 8 | 0.115 | 2.9 | 0.11 | 2.8 | 1.74 | 44.2 | 2656 | 3952 | 211 |
3×2/0 | 19 | 3 | 8 | 0.115 | 2.9 | 0.14 | 3.6 | 1.90 | 48.3 | 2895 | 4307 | 243 |
3×3/0 | 19 | 2 | 8 | 0.115 | 2.9 | 0.14 | 3.6 | 2.00 | 50.8 | 3320 | 4950 | 279 |
3×4/0 | 19 | 1 | 8 | 0.115 | 2.9 | 0.14 | 3.6 | 2.12 | 53.8 | 3983 | 5926 | 321 |
3×250 | 37 | 1/0 | 8 | 0.115 | 2.9 | 0.14 | 3.6 | 2.22 | 56.4 | 4484 | 6671 | 355 |
3×350 | 37 | 2/0 | 8 | 0.115 | 2.9 | 0.14 | 3.6 | 2.43 | 61.7 | 5827 | 8669 | 435 |
3×500 | 37 | 4/0 | 8 | 0.115 | 2.9 | 0.14 | 3.6 | 2.70 | 68.6 | 7893 | 11743 | 536 |
Ampacity-Based on a conductor temperature of 90℃ and an ambient air temperature of 40℃, per ICEA S-75-381.
In underground and surface mining operations, power reliability is not optional—it is mission-critical. When operators search for “Type MP-GC 8kV mine power feeder cable”, they are usually trying to answer three key questions: What exactly is this cable? Where should it be used? And how does it compare with other mining power cables?
The Feichun Type MP-GC Three-Conductor Mine Power Feeder Cable with PVC Jacket (8kV) is specifically designed for connections between units of mine distribution systems, offering a balance of electrical performance, mechanical robustness, and regulatory compliance under ICEA S-75-381.
What Does “Type MP-GC 8kV” Mean in Mining Power Applications?
The designation MP-GC is not a marketing term—it defines a Mine Power – Ground Check cable designed for medium-voltage distribution in mining environments.
MP: Mine Power, suitable for feeder and distribution circuits
GC: Integrated ground check conductor for continuous grounding integrity monitoring
8kV: Rated voltage class suitable for mine distribution systems between substations, switchgear, and major equipment
This makes Type MP-GC cables ideal for fixed or semi-fixed installations, unlike highly flexible trailing or reeling cables.
What Is the Purpose of the Ground Check and Grounding Conductors?
Why Is a Ground Check Conductor Required?
The ground check conductor, insulated with yellow polypropylene, enables continuous monitoring of the grounding circuit. If grounding continuity is lost, protective systems can trip power automatically—critical for miner safety.
How Does the Grounding Conductor Enhance Fault Protection?
A tinned copper grounding conductor provides:
Low-resistance fault current path
Improved corrosion resistance in wet or acidic mine conditions
Compliance with ICEA and CSA safety requirements
Why Choose a PVC Jacket for Mine Power Feeder Cables?
The outer jacket is made of black Polyvinyl Chloride (PVC), offering:
Resistance to moisture, oils, and chemicals
Good abrasion performance in ducts and open installations
Cost-effective protection for fixed mining installations
For harsher environments, Feichun also offers CSP, PCP, NBR, CPE, and TPU jackets upon request.
How Do Different MP-GC 8kV Sizes Compare?
Which Conductor Size Should You Choose?
Below is a simplified comparison based on ampacity and application:
Cable Size | Ampacity (A) | Typical Application |
|---|---|---|
3×4 AWG | 122 A | Small mine distribution feeders |
3×1/0 AWG | 211 A | Section substations |
3×4/0 AWG | 321 A | Main underground feeders |
3×350 kcmil | 435 A | High-load mine power networks |
3×500 kcmil | 536 A | Primary mine distribution circuits |
Choosing the correct size depends on load demand, installation method, and future expansion planning.
How Does Type MP-GC Compare with Other Mining Power Cables?
MP-GC vs SHD-GC vs Trailing Cables
Feature | MP-GC 8kV | SHD-GC | Trailing Cable |
|---|---|---|---|
Installation | Fixed / semi-fixed | Portable | Highly flexible |
Voltage Class | Medium (up to 8kV) | Medium to high | Low to medium |
Ground Check | Yes | Yes | Yes |
Mechanical Flexibility | Moderate | High | Very high |
Typical Use | Mine distribution | Mobile equipment | Continuous miners |
MP-GC is the preferred choice for stable, long-term power feeders, not constantly moving machinery.
Frequently Asked Questions About Type MP-GC 8kV Cables
Is Type MP-GC Suitable for Mobile Mining Equipment?
No. MP-GC cables are designed for fixed or semi-fixed distribution, not continuous movement.
Can PVC Jackets Be Used in Wet Mine Conditions?
Yes. PVC performs well in wet environments, though CPE or TPU may be preferred for extreme mechanical abuse.
Does MP-GC Meet International Standards?
Yes. The cable complies with:
ICEA S-75-381 / NEMA WC 58
ASTM B-8
CAN/CSA-C22.2 No.96
Why Choose Feichun Type MP-GC 8kV for Your Mine Power System?
Feichun’s MP-GC cables offer:
Proven compliance with international mining standards
Flexible sizing for diverse mine layouts
Reliable grounding and safety features
Custom jacket options for harsh environments
If you are planning a mine power distribution upgrade or expansion, selecting the correct MP-GC cable size and construction is critical for safety and efficiency.
Contact Feichun’s technical team today to request datasheets, sizing assistance, or customized solutions tailored to your mining environment.
Kabel Pertambangan Feichun
Kabel pertambangan yang tahan lama untuk lingkungan dan operasi yang berat
Alamat Email
© 2025. All rights reserved.


Produk
Kabel Tambang AS/NZS
Kabel Tambang DIN VDE
Kabel Tambang BS 6708
Kabel Tambang ICEA & CAN/CSA
Kabel Berselubung Baja
Kabel Gulung / Kabel Reeling
Kabel Festoon / Kabel Rel Kren
Perusahaan
Kontak
WhatsApp: +86 17333223430
Social Media: