General Information

Cable Type

NTSCGEWOU

Voltage Ratings (Uo/U)

3.6/6 kV, 6/10 kV, 8.7/15 kV, 12/20 kV

Application

Flexible cable for fixed distribution lines in mines and alongside material handling equipment. Suitable for indoor and outdoor applications.

Maximum Torsional Stress

±25°/m

Maximum Working Speed

20 m/min

Maximum Short Circuit Temperature

250°C

Operating Temperature (Mobile)

-25°C to +80°C

Operating Temperature (Static)

-40°C to +80°C

Minimum Bending Radius (Fixed)

6 x overall diameter

Note

(N)TSCGEWOU ATB is available with Anti-Torsion Braid

Construction Details

Component

Material / Description

Phase Conductor

Class 5 flexible stranded tinned copper

Insulation

Rubber compound

Semi-Conductive Layers

Semi-conductive tape over the conductor and inner & outer semi-conductive rubber layer on the insulation

Earth Conductor

Class 5 tinned copper conductor

Central Filler

Semi-conductive compound on a textile polyester support

Inner Sheath

Rubber compound

Anti-Torsion Braid

Polyester

Outer Sheath

Rubber compound

Sheath Colour

Yellow

Standards & Certifications

Item

Details

Third-Party Accreditation

VDE approved – Cables are tested and approved by the VDE Testing & Certification Institute

Standards

VDE 0295, IEC 60228, VDE 0207 Part 20 & 21, VDE 0250 Part 813, VDE 0298 Part 3, IEC 60811-2-1, EN 60228

Flame Retardant

According to IEC/EN 60332-1-2

DIMENSIONS & CURRENT CARRYING CAPACITY

Voltage (kV)

No. of Cores (Phase+Earth)

Nominal Cross Section (mm²)

Conductor Diameter (Phase mm)

Conductor Diameter (Earth mm)

Overall Diameter (mm)

Nominal Tensile Load (N)

Max Weight (kg/km)

Current Carrying Capacity (Amps, 30°C)

Reeled Current Capacity (Amps)

3.6/6

3+3

25

25/3

6.9

39.7

1500

2380

131

80 (2 Layer), 64 (3 Layer), 55 (4 Layer), 50 (5 Layer), 35 (6 Layer), 29 (7 Layer)

3.6/6

3+3

35

25/3

7.8

43.7

2100

2920

162

99, 79, 68, 62, 44, 36

3.6/6

3+3

50

25/3

9.3

46.8

3000

3520

202

123, 99, 85, 77, 55, 44

3.6/6

3+3

70

35/3

11.1

50.7

4200

4430

250

153, 123, 105, 95, 68, 55

3.6/6

3+3

95

50/3

12.7

56.7

5700

5580

301

184, 147, 126, 114, 81, 66

6/10

3+3

120

70/3

14.5

60.5

7200

6770

352

215, 172, 148, 134, 95, 77

6/10

3+3

150

70/3

16.7

67.15

9000

8260

404

246, 198, 170, 154, 109, 89

6/10

3+3

185

95/3

17.6

69

11100

9400

461

281, 226, 194, 175, 124, 101

8.7/15

3+3

25

25/3

6.9

39.7

1500

2380

131

80, 64, 55, 50, 35, 29

8.7/15

3+3

35

25/3

7.8

43.7

2100

2920

162

99, 79, 68, 62, 44, 36

8.7/15

3+3

50

25/3

9.3

46.8

3000

3520

202

123, 99, 85, 77, 55, 44

8.7/15

3+3

70

35/3

11.1

50.7

4200

4430

250

153, 123, 105, 95, 68, 55

8.7/15

3+3

95

50/3

12.7

56.7

5700

5870

301

184, 147, 126, 114, 81, 66

8.7/15

3+3

120

70/3

14.5

65

7200

7370

352

215, 172, 148, 134, 95, 77

8.7/15

3+3

150

70/3

16.7

69.7

9000

8590

404

246, 198, 170, 154, 109, 89

8.7/15

3+3

185

96/3

17.6

71.8

11100

9750

461

281, 226, 194, 175, 124, 101

12/20

3+3

25

25/3

6.9

45.5

1500

2860

131

80, 64, 55, 50, 35, 29

12/20

3+3

35

25/3

7.8

47

2100

3210

162

99, 79, 68, 62, 44, 36

12/20

3+3

50

25/3

9.3

50.3

3000

3830

202

123, 99, 85, 77, 55, 44

12/20

3+3

70

35/3

11.1

55.9

4200

5000

250

153, 123, 105, 95, 68, 55

12/20

3+3

95

50/3

12.7

59.3

5700

5870

301

184, 147, 126, 114, 81, 66

12/20

3+3

120

70/3

14.5

65

7200

7370

352

215, 172, 148, 134, 95, 77

12/20

3+3

150

70/3

16.7

69.7

9000

8590

404

246, 198, 170, 154, 109, 89

12/20

3+3

185

95/3

17.6

71.8

11100

9750

461

281, 226, 194, 175, 124, 101

Flexible, durable, and technically advanced, the NTSCGEWOU cable series is becoming a critical component in mining and material handling industries worldwide. Designed for high mechanical stress environments, these VDE and IEC-certified cables combine flame retardancy, rubber insulation, and robust construction, making them ideal for both underground mines and surface material handling operations. But what exactly makes NTSCGEWOU cables stand out, and how do their technical specifications, structure, and applications impact real-world performance, particularly in Indonesia’s mining sector?

What Are the Key Features and Construction of NTSCGEWOU Cables?

The NTSCGEWOU cable series is built to withstand high mechanical and environmental stresses while maintaining optimal electrical performance.

Conductor and Insulation

At the core, NTSCGEWOU cables feature Class 5 flexible stranded tinned copper conductors, ensuring excellent conductivity and flexibility for mobile and fixed installations. The insulation uses a high-quality rubber compound, providing resistance against abrasion, mechanical stress, and temperature fluctuations.

Semi-Conductive Layers and Earth Conductor

Each phase conductor is wrapped with semi-conductive tape and rubber layers, which stabilize the electric field and enhance insulation performance. A Class 5 tinned copper earth conductor ensures safety and grounding compliance.

Fillers, Sheaths, and Anti-Torsion Features

The cable includes a semi-conductive compound on textile polyester support as the central filler, contributing to flexibility. An inner rubber sheath provides additional protection, while an outer rubber sheath, typically yellow, protects against external mechanical and environmental damage. Certain models are equipped with an anti-torsion polyester braid, making them suitable for applications with high twisting or reeling movements.


Where Are NTSCGEWOU Cables Typically Used?

The versatility of NTSCGEWOU cables makes them suitable for multiple industrial scenarios:

  • Mining Applications: Ideal for fixed distribution lines and mobile equipment in underground and surface mines, resistant to high mechanical stress, torsion, and temperature variations.

  • Material Handling Systems: Widely used alongside conveyors, cranes, and reeling equipment where flexibility and durability are critical.

  • Indoor and Outdoor Installations: Suitable for both environments due to robust rubber insulation and flame-retardant properties.

Case Study: Indonesia

In Indonesia’s coal and nickel mining operations, NTSCGEWOU cables have been successfully deployed for:

  • Coal conveyor systems: Cables maintain electrical integrity despite high-speed mechanical movement and dust exposure.

  • Underground mining: Mobile drilling and extraction equipment rely on NTSCGEWOU for continuous power, even in high humidity and extreme temperature variations.

  • Material handling at ports: Cranes and heavy container equipment use these cables for reliability in dynamic load conditions.

This demonstrates that the NTSCGEWOU series is not just theoretically suitable but proven in real industrial environments.


What Are the Electrical and Mechanical Parameters of NTSCGEWOU Cables?

Electrical performance is critical for safety and efficiency. NTSCGEWOU cables provide:

  • Current Carrying Capacity: Up to 484 Amps for 185 mm² conductors (air, free section)

  • Tensile Load Capacity: Up to 11,100 N for larger conductors

  • Nominal Diameters: Range from 39.7 mm to 71.8 mm, depending on cross-sectional area

Mechanically, they offer:

  • Reeling Capability: Multiple layers can be reeled with high current load retention.

  • Bending Radius: Minimum 6x overall diameter for fixed installation.

  • Temperature Resilience: Operates reliably from -40°C to +80°C in static conditions.


Frequently Asked Questions (FAQ) About NTSCGEWOU Cables

1. What makes NTSCGEWOU cables suitable for mining applications?

NTSCGEWOU cables are designed to withstand extreme mechanical stress, torsion, temperature variation, and abrasion, making them ideal for mobile and stationary mining equipment. Their rubber insulation, semi-conductive layers, and VDE/IEC certifications ensure safety and durability underground.

2. How does NTSCGEWOU compare with PVC-insulated cables?

Unlike PVC-insulated cables, NTSCGEWOU offers higher temperature tolerance, better flexibility, and flame retardancy, making it suitable for high-stress industrial applications.

3. Can NTSCGEWOU cables be used for outdoor applications?

Yes. The robust rubber outer sheath and flame-retardant properties allow installation both indoors and outdoors, including in tropical climates like Indonesia.

4. What voltage ranges are available for NTSCGEWOU?

NTSCGEWOU cables support 3.6/6kV, 6/10kV, 8.7/15kV, and 12/20kV, providing flexibility for various power distribution requirements.

5. How should NTSCGEWOU cables be maintained in high-use environments?

Regular visual inspections, monitoring for abrasion or mechanical damage, and ensuring proper support during reeling or bending will maintain performance. Avoid exceeding torsional stress and bending radius limits.

6. Are NTSCGEWOU cables flame retardant?

Yes. NTSCGEWOU cables comply with IEC/EN 60332-1-2, ensuring reduced fire risk in critical industrial installations.

7. How do I choose the right NTSCGEWOU size for my application?

Choose based on current carrying capacity, conductor cross-section, voltage rating, and installation type (fixed vs. mobile). Refer to the manufacturer’s technical data table for exact specifications.


Why Choose NTSCGEWOU for Your Industrial and Mining Needs?

NTSCGEWOU cables offer:

  • Flexibility and durability under torsion and reeling conditions.

  • High mechanical and thermal resistance for underground and surface applications.

  • Certified safety compliance (VDE & IEC) for flame retardancy and electrical standards.

  • Proven performance in Indonesia’s mining operations, from coal to nickel extraction.

Whether for material handling equipment, mobile mining machinery, or fixed underground installations, NTSCGEWOU ensures safety, reliability, and long-term operational efficiency.


If you are involved in mining, material handling, or industrial power distribution in Indonesia or Southeast Asia, choosing the NTSCGEWOU flexible mining cable can significantly reduce downtime and maintenance costs while improving safety standards. Contact certified suppliers to discuss the best NTSCGEWOU configuration for your operations and request a detailed installation guide.