ICEA S-75-381 Type MP-GC Three-Conductor Mine Power Feeder Cable CPE Jacket 5kV

Applications :

These cables are designed for connections between units of mine distribution systems, suitable for installed in duct, conduit or open air and for direct burial in wet and dry locations.

Standards :

ICEA S-75-381/NEMA WC 58

 

ASTM B-8

 

CAN/CSA-C22.2 No.96

Construction :

Conductor

Stranded annealed bare copper conductor.

Conductor Shield

Conducting layer.

Insulation

Ethylene Propylene Rubber (EPR).

Insulation Shield

Conducting layer + copper tape.

Ground Check Conductor

Copper conductor with a yellow polypropylene insulation.

Grounding Conductor

Tinned copper conductor.

Jacket

Chlorinated Polyethylene (CPE), black.

Options :

  • Other jacket materials such as CSP/PCP/NBR/PVC/TPU are available upon request.

Mechanical and Thermal Properties :

  • Minimum Bending Radius: 12×OD.

  • Maximum Conductor Operating Temperature: +90℃.

Dimensions and Weight :

Construction

No. of
Strands

Grounding
Conductor
Size

Ground
Check
Conductor
Size

Nominal Insulation
Thickness

Nominal Jacket
Thickness

Nominal Overall
Diameter

Nominal Weight

Ampacity

No. of cores
×AWG/kcmil

-

AWG/
kcmil

AWG/
kcmil

inch

mm

inch

mm

inch

mm

lbs/kft

kg/km

A

3×6

7

10

8

0.09

2.3

0.11

2.8

1.30

33.0

1060

1577

93

3×4

7

8

8

0.09

2.3

0.11

2.8

1.41

35.8

1441

2144

122

3×2

7

6

8

0.09

2.3

0.11

2.8

1.47

37.3

1827

2718

159

3×1

19

5

8

0.09

2.3

0.11

2.8

1.54

39.1

2168

3226

184

3×1/0

19

4

8

0.09

2.3

0.11

2.8

1.63

41.4

2602

3871

211

3×2/0

19

3

8

0.09

2.3

0.11

2.8

1.72

43.7

3010

4478

243

3×3/0

19

2

8

0.09

2.3

0.14

3.6

1.89

48.0

3265

4859

279

3×4/0

19

1

8

0.09

2.3

0.14

3.6

2.01

51.0

4190

6234

321

3×250

37

1/0

8

0.09

2.3

0.14

3.6

2.10

53.3

4825

7179

355

3×350

37

2/0

8

0.09

2.3

0.14

3.6

2.31

58.7

6062

9019

435

3×500

37

4/0

8

0.09

2.3

0.14

3.6

2.59

65.8

8427

12538

536

In underground and surface mining operations, power reliability is not optional—it is a safety requirement. As mines expand deeper and equipment loads increase, selecting the right Mine Power Feeder Cable becomes critical. One of the most widely specified designs for fixed and semi-fixed mine power distribution is the ICEA S-75-381 Type MP-GC Three-Conductor Mine Power Feeder Cable (5kV, CPE Jacket).

What Does “Type MP-GC” Mean in Mining Power Cables?

Type MP-GC is a classification defined under ICEA S-75-381 / NEMA WC 58, specifically for Mine Power Feeder Cables used in mining distribution systems.

  • MP = Mine Power

  • GC = Ground Check conductor included

Unlike trailing or reeling cables, MP-GC cables are designed for feeder circuits, supplying power between substations, switchgear, transformers, and load centers.

How Is a Type MP-GC Mine Power Feeder Cable Constructed?

The strength of the Type MP-GC cable lies in its multi-layered, safety-oriented construction.

What Type of Conductor Is Used?

  • Stranded annealed bare copper

  • Manufactured to ASTM B-8

  • High flexibility compared to solid conductors

  • Excellent conductivity and fatigue resistance

Why Is a Conductor Shield Necessary?

A conductive shield layer surrounds each conductor to:

  • Control electric stress

  • Prevent partial discharge

  • Improve insulation life at 5kV

What Insulation Material Is Used and Why?

  • EPR (Ethylene Propylene Rubber) insulation

  • Rated for 90°C continuous operation

  • Superior resistance to:

    • Moisture

    • Heat aging

    • Electrical stress

    • Ozone and chemicals

What Is the Role of the Insulation Shield and Copper Tape?

  • Conductive insulation shield + copper tape

  • Ensures:

    • Uniform grounding

    • Fast fault current dissipation

    • Improved personnel safety

Why Are Separate Grounding and Ground-Check Conductors Included?

  • Grounding Conductor: Tinned copper (corrosion-resistant)

  • Ground Check Conductor: Copper with yellow polypropylene insulation

  • Enables continuous monitoring of grounding integrity—critical in mines

Why Is a CPE Jacket Used?

The outer Chlorinated Polyethylene (CPE) jacket provides:

  • High abrasion resistance

  • Flame resistance

  • Oil, chemical, and moisture resistance

  • Long service life in ducts, conduits, and direct burial


Where Are Type MP-GC Mine Power Feeder Cables Commonly Used?

Typical Applications

  • Underground mine substations

  • Power feeders between transformers and switchgear

  • Conveyor power supply systems

  • Pump stations

  • Ventilation fan feeders

  • Fixed mining infrastructure

Installation Environments

  • Installed in ducts

  • Installed in conduits

  • Installed in open air

  • Direct burial in wet or dry soil


How Does Type MP-GC Compare with Other Mining Power Cables?

MP-GC vs SHD-GC vs G-GC

Feature

MP-GC

SHD-GC

G-GC

Voltage

Up to 5kV

Up to 25kV

Up to 2kV

Application

Power feeder

Mobile equipment

Mobile equipment

Flexibility

Medium

High

High

Ground Check

Yes

Yes

Yes

Installation

Fixed

Trailing/Reeling

Trailing


What Are the Key Installation Recommendations for MP-GC Cables?

Best Practices

  • Maintain minimum bending radius

  • Ensure proper grounding and ground-check continuity

  • Use cable cleats in vertical installations

  • Avoid sharp rocks in direct burial

  • Perform insulation resistance testing before energizing


Frequently Asked Questions (FAQ)

Is Type MP-GC suitable for mobile mining equipment?

No. It is designed for fixed or semi-fixed feeder applications, not trailing use.

Can MP-GC cables be directly buried underground?

Yes. They are designed for direct burial in wet and dry conditions.

Why is a ground check conductor mandatory in mining?

It ensures continuous monitoring of grounding integrity, reducing electric shock risk.

Is CPE better than PVC for mining cables?

Yes. CPE offers superior resistance to heat, oil, abrasion, and flame.

Can alternative jacket materials be supplied?

Yes. CSP, PCP, NBR, PVC, and TPU jackets are available upon request.


Why Choose Feichun Type MP-GC Mine Power Feeder Cable?

  • Fully compliant with ICEA S-75-381

  • Proven performance in harsh mining environments

  • Broad size and ampacity range

  • Custom jacket options

  • Trusted by global mining projects