Anhui Feichun Special Cable Co.,Ltd
FG7H1OAR Kabel Fleksibel 3.6/6kV & 6/10kV untuk Peralatan Tegangan Menengah, Tunneling & Pertambangan Bawah Tanah IEC 60502-2, Flame Retardant
FG7H1OAR 3.6/6kV dan 6/10kV Kabel
APLIKASI
Kabel fleksibel untuk pasokan energi pada peralatan tegangan menengah (MV), digunakan di terowongan dan pertambangan bawah tanah. Cocok untuk penggunaan di dalam dan luar ruangan.
KARAKTERISTIK
Tegangan Nominal (Uo/U)
3,6/6 kV
6/10 kV
Tegangan Uji
3,6/6 kV: 12,5 kV
6/10 kV: 21 kV
Suhu Lingkungan
Tetap: -40°C hingga +80°C
Fleksibel: +5°C hingga +80°C
Suhu Maksimum Arus Hubung Singkat: +250°C
Radius Minimum Pembengkokan
Tetap: 6 x diameter keseluruhan
Fleksibel: 10 x diameter keseluruhan
KONSTRUKSI
Konduktor Fase: Tembaga timah kelas 5
Isolasi: HEPR (Hard Ethylene Propylene Rubber)
Lapisan Semi-Konduktif: Pita semi-konduktif di atas konduktor dan lapisan karet semi-konduktif dalam & luar pada isolasi
Konduktor Pengaman (PE): Anyaman kawat tembaga individual
Konduktor Kontrol: Tembaga timah kelas 5
Pengisi Pusat: Campuran karet pada penyangga tekstil poliester
Selubung Dalam: PVC (Polyvinyl Chloride)
Armour: Anyaman kawat baja di atas selubung dalam
Selubung Luar: PVC (Polyvinyl Chloride)
Warna Selubung: Merah
STANDAR
Umumnya sesuai IEC 60502-2, IEC 60228
Tahan Api sesuai IEC/EN 60332-1-2
DIMENSI


The FG7H1OAR flexible cable is rapidly gaining attention in industrial, tunneling, and underground mining sectors across Indonesia. Designed for medium-voltage (MV) equipment and applications exposed to mechanical stress, its flame-retardant properties and robust construction make it a trusted solution for reliable energy distribution in challenging environments.
What Are the Main Features of FG7H1OAR 3.6/6kV and 6/10kV Cables?
FG7H1OAR cables are designed for flexible energy supply to medium-voltage equipment, particularly in tunnels and underground mines. The main features include:
Voltage Ratings: 3.6/6kV and 6/10kV
Test Voltage: 12.5kV (3.6/6kV) and 21kV (6/10kV)
Temperature Range: Fixed: -40°C to +80°C, Flexed: +5°C to +80°C
Maximum Short-Circuit Temperature: +250°C
Minimum Bending Radius: Fixed: 6× overall diameter, Flexed: 10× overall diameter
Flame Retardant: Complies with IEC/EN 60332-1-2
The combination of mechanical resilience and flame-retardant properties ensures safety, reliability, and long service life in demanding environments.
What Are the Typical Applications of FG7H1OAR Cables?
FG7H1OAR cables are widely used in tunnels, underground mining, and medium-voltage distribution systems:
Underground Mining: Powering heavy machinery such as drills, shovels, and conveyors.
Tunneling Projects: Providing flexible energy distribution for tunnel boring machines (TBMs).
Medium Voltage Equipment: Supply to switchgear, transformers, and industrial motors.
Indoor and Outdoor Installations: Resistant to moisture, dust, and mechanical impact.
Real Indonesian Use Case: Grasberg Mine, Papua
In Papua’s Grasberg underground mine, FG7H1OAR 6/10kV cables were deployed to power tunneling machines under extreme mechanical stress. The steel wire braid armour protected the cable from abrasion against rock walls, while the PVC sheath allowed long-term exposure to high humidity without degradation.
How Does FG7H1OAR Compare with Other MV Mining Cables?
Feature | FG7H1OAR | Standard XLPE MV Cable | Reeling Cable |
|---|---|---|---|
Voltage Range | 3.6/6 & 6/10 kV | 6/10 kV | 3.6/6 kV |
Flexibility | High | Medium | Very High |
Flame Retardant | IEC 60332-1-2 | IEC 60332 | IEC 60332 |
Mechanical Protection | Steel wire braid | None or light armouring | Reinforced |
Indoor/Outdoor | Yes | Limited outdoor | Limited outdoor |
Ideal Use | Tunneling & underground mining | Fixed distribution | Mobile equipment |
FG7H1OAR combines flexibility, mechanical protection, and flame retardancy, making it ideal for medium-voltage industrial environments with high mechanical stress.
Frequently Asked Questions (FAQ)
Can FG7H1OAR cables be used in open-pit mines?
Yes, the cables are suitable for outdoor applications, including open-pit mining. However, for extreme sunlight exposure, additional UV protection is recommended.
How does FG7H1OAR differ from standard XLPE MV cables?
FG7H1OAR uses HEPR insulation for superior flexibility and abrasion resistance, while standard XLPE cables are stiffer and less suited for bending-intensive applications.
What maintenance is required for FG7H1OAR in underground mining?
Routine inspection of the PVC sheath and steel wire armour is sufficient. Look for cuts, abrasions, or heat damage. Voltage drop monitoring is recommended for long cable runs.
Can these cables handle short-circuit events?
Yes. The maximum short-circuit temperature is +250°C. Correctly sized cables, according to cross-section and load, can safely handle short-circuit conditions.
What is the recommended bending radius for installation?
Fixed: 6× overall diameter
Flexed: 10× overall diameter
Are FG7H1OAR cables flame-retardant?
Yes. They comply with IEC/EN 60332-1-2, ensuring reduced fire propagation in case of an incident.
Why Choose FG7H1OAR for Your Project?
FG7H1OAR cables offer flexibility, durability, flame retardancy, and mechanical protection, making them the optimal choice for medium-voltage distribution in:
Underground mining operations
Tunneling projects
Industrial plants with mobile heavy equipment
By selecting FG7H1OAR, engineers can reduce downtime, maintenance costs, and safety risks.
For reliable, high-performance medium-voltage cable solutions, FG7H1OAR 3.6/6kV and 6/10kV flexible cables provide long-lasting safety and operational efficiency. Contact our team for:
Project-specific cable sizing
Technical consultations
Installation guidance and supply
Ensure your mining or tunneling project achieves maximum safety and energy efficiency today.

Feichun Cable
Durable mining cables for tough environments and operations
Email: Li.wang@feichuncables.com
© 2025. All rights reserved.


Company
Products
Contact
WhatsApp: +86 17333223430